News: 27th January 2025
Plans submitted to Epsom & Ewell Borough Council for a house extension and loft conversion to a house in Manor Green Road
Plans have now been submitted to Epsom & Ewell Borough Council for a substantial first floor side and rear extension and loft conversion to this large detached house in Manor Green Road.
The site lies within Flood Zone 3 whilst also bordering Flood Zones 1 and 2.
NPPF guidlelines state that in cases such as this the highest Flood Zone should be used for assessment which is Flood Zone 3 which ends to the rear of the site. Epsom & ewell's flood mapping shows that part of the site lies in Flood Zone 3b which is the functional flood plan. However, most of the site is within Flood Zone 1.
It is not considered that extensions to the first floor would be threatened by flooding as they would be above any possible flooding level, even taking into account projections allowing for climate change. However, the proposed garage with a footprint of 30square metres is replacing an outbuilding of footprint circa 4square metres so equating to an increase in footprint of 26square metres. With this increase in footprint comes the risk that the proposed garage could compromise the flow of water away from the site and therefore lead to an increased risk of flooding.
To mitigate the chances of this happening, the proposed garage will be of brick construction, perforated along a single course around 300mm above the ground level to make the garage floodable and there will be sufficient time for the site owner to open the main entry door to the garage to allow the flood water to follow it's natural course away from the development.
Flood Resilience Measures:
1. Both the interior and exterior of the garage will be coated in a flood resistent material to a height of 400mm above ground floor level.
2. All electrical wiring will drop from the ceiling to sockets located a minimum of 400mm above ground floor level.
3. All drainage and waste pipes will be fitted with non-return valves to prevent the ingress of contaminated water back into the building.
4. No metal will be used under the proposed to abort future corrosion.
5. The ground floor will be concrete rather than wood.
6. The electrics should be connected to the mans box in the house so that this controls all electrics to the whole property.
Sustainable drainage
Waterbutts will be used for harvesting rainwater run-off from the garage. In the event of an exceptional storm the buts may overtop and a French drain should be installed to take any surplus water to a drain which is in place to channel the water to an attenuation area within the curtilage of the site. This drain will have a protective covering along it's length to ensure that it does not collect any detritus and regular checks must be made on it's condition.
The waterbutts could also be used for vehicle washing, washing down external piantwor and irrigation for the garden during the summer months. The water could also be piped into the house for handwashing and toilet flushing as well as household washing.
Flow off the extensions on the first floor of the house will be little more than existing. It will be channelled into an existing soakaway.
The Epsom & Ewel Borough Council mapping for ground conditions shows that this area falls in a large swathe of permeable soil consisting of silt, sand and gravel interspersed with elemants of clay.
Conclusion
As the proposed garage will have a footprint under 250square metres it is considered to be a minor development under NPPF criteria.
This special section also states that the sequential test is not considered necessary.
The NNPF has always indicated that local authorities should be pragmatic to such cases.
The criteria of the EA and the NNPF are goverment documents which have not been compiled to stop proposed development but to act as an aid to all invloved to steer planning applications to a successful outcome.